item
项目
|
content
详细内容
|
criterion
标准
|
电压采集精度
|
典型10mv 最大20mv
|
|
电流采集精度
|
典型1%最大2%
|
|
soc精度
|
典型5%最大8%
|
|
over charge
protection
过充保护
|
over charge detection voltage
过充电检测电压
|
3.6~4.25v可设置
|
over charge detection delay time
过充电检测延迟时间
|
0.1 s ~ 6s可设置
|
over charge release voltage
过充电恢复电压
|
3.5~4.25v可设置
|
over discharge
protection
过放保护
|
over discharge detection voltage
过放电检测电压
|
2.0~3.3v可设置
|
over discharge detection delay time
过放电检测延迟时间
|
0.1 s ~ 6s可设置
|
over discharge release voltage
过放电恢复电压
|
2.1~3.4v可设置
|
charge
over current protection
充电过流保护
|
charge over current detection current
充电过电流保护电流
|
1~100a可设置
|
charge over current detection delay time
充电过流检测延迟时间
|
0.02s~ 6s可设置
|
discharge
over current
protection
放电过流保护
|
discharge over current detection current
放电过电流保护电流
|
1~300a可设置
|
discharge over current detection delay time
放电过流检测延迟时间
|
0.02s~ 6s可设置
|
short
protection
短路保护
|
short protection detection delay time
(硬件)短路保护延迟时间
|
100 u s
|
detection condition
保护条件
|
电池组b 对p-接线线头短路或空气开关加0.2欧姆电阻短路
|
短路保护解除条件
|
断开负载
|
interior
resistance 内阻
|
main loop electrify resistance
主回路通态电阻
|
2 毫欧姆(50a测定)
|
currentconsumption
消耗电流
|
current consume in normal operation
工作时电路内部消耗
|
1.5ma type
|
currentconsumption
休眠消耗电流
|
current consume in sleep operation
休眠时电路内部消耗(无使用10分钟进入休眠)
|
200 ua type
|
充放电高温保护
|
|
0 ℃~200℃可设置
|
充放电高温保护恢复
|
|
0 ℃~200℃可设置
|
充放电低温保护
|
|
-60℃~60℃ 可设置
|
充放电低温保护恢复
|
|
-60℃~60℃ 可设置
|
平衡开启电压
|
|
3 ~ 4.35v 可设置
|
平衡电流
|
|
80ma
|
额定放电电流
|
根据客户实际选配,最大200a同口持续,支持100a持续充电200a持续放电
|
200a 脉冲400a(40s)
|
断线保护检测时间
|
|
2秒
|
断线保护恢复条件
|
|
维修接线,否则,不可充放电
|